Q.Predict the products of electrolysis in each of the following:
🔒You're viewing a preview — the full solution, concept, methods & PYQ mapping are locked.
🔒 Start your 14-day free trial to unlock the full solution →Concept understanding — Standard Electrode Potentials
Standard Electrode Potentials: A Number for "How Badly It Wants Electrons"
Dip a zinc rod into a zinc-salt solution and a tiny tug-of-war begins at the surface:
metal atoms tend to dissolve as ions (leaving electrons behind on the rod) while ions
from the solution tend to deposit as metal (consuming electrons). The rod ends up with
a characteristic electrical potential relative to the solution — the electrode potential. It is a direct measure of the tendency of that redox couple to gain or
lose electrons.
The Core Idea
Different couples pull electrons with very different strengths. Copper's ion grabs
them readily; zinc's barely wants them. Put a number on each couple and you can
predict, before mixing anything, who will oxidise whom.
Two conventions make the numbers comparable:
- Standard conditions. Every species at unit concentration (1 M), any gas at 1 atm, temperature 298 K. The potential measured then is the standard electrode potential, written E⊖.
- A common zero. Potentials can only be measured as differences, so one electrode is defined as the reference: the standard hydrogen electrode (SHE), 2H++2e−→H2, is fixed at exactly 0.00 V. Every E⊖ is the voltage of a couple measured against it.
By convention the values are tabulated for the reduction direction:
Oxidised form+ne−→Reduced formE⊖ (in volts, at 298 K)
Reading the Table
The standard-potential table (Table 7.1 in the Class 11 chapter) runs from
F2/F− at +2.87 V down to Li+/Li at −3.05 V.
Two rules unlock it:
- More positive E⊖ → stronger oxidising agent (the oxidised form is hungrier for electrons). F₂ tops the table; that is why fluorine oxidises almost everything.
- More negative E⊖ → stronger reducing agent (the reduced form gives electrons up most easily). Li, K, Ca, Na at the bottom are the great electron donors. A negative E⊖ means the couple is a stronger reducing agent than the H⁺/H₂ couple; a positive one, weaker.
Predicting Whether a Reaction Goes
For any proposed redox reaction, the species being reduced acts as the cathode couple
and the species being oxidised as the anode couple:
Ecell⊖=Ecathode⊖−Eanode⊖
A positive Ecell⊖ means the reaction is feasible
(spontaneous) under standard conditions; a negative one means the reverse reaction
is the spontaneous direction.
Worked feel: can Fe³⁺ oxidise iodide? E⊖(Fe3+/Fe2+)=+0.77 V is above E⊖(I2/I−)=+0.54 V, so
Ecell⊖=+0.23 V — yes. Can silver metal reduce Fe³⁺?
0.77−0.80=−0.03 V — no.
This is also the logic of the activity series: a metal displaces, from solution, …
Why this formula?
Galvanic Corrosion: Why the Key Formulas Hold
Galvanic corrosion occurs when two dissimilar metals are electrically connected in the presence of an electrolyte. The key formula that governs this is the mixed potential theory, which leads to the galvanic current and corrosion rate expressions.
Let's build the reasoning step-by-step.
1. The Core Idea: Two Electrodes, One Circuit
When metals M₁ (more active, e.g., zinc) and M₂ (more noble, e.g., copper) are connected:
- M₁ acts as the anode — it oxidizes (corrodes):
M1→M1n++ne−
- M₂ acts as the cathode — it reduces something (e.g., oxygen or H⁺):
O2+2H2O+4e−→4OH−(in neutral/alkaline)
or
2H++2e−→H2(in acidic)
The two metals are electrically connected (via a wire or direct contact), and the electrolyte completes the circuit. Electrons flow from M₁ to M₂.
2. The Mixed Potential: Why It Exists
Each metal, when alone in the electrolyte, has its own open-circuit potential (OCP) — the equilibrium potential for its half-reaction. For M₁, it's Ecorr,1; for M₂, it's Ecorr,2.
When connected, the system cannot stay at two different potentials. The entire metal couple must reach a single potential — the mixed potential Emix.
- Emix lies between Ecorr,1 and Ecorr,2.
- At Emix, the total anodic current from M₁ equals the total cathodic current from M₂ (charge conservation):
Ianode=Icathode
This is the fundamental equation of galvanic corrosion.
3. Deriving the Galvanic Current
Assume each electrode follows Butler-Volmer kinetics (for activation-controlled reactions). For the anode (M₁), the anodic current density ia at potential E is:
ia=i0,1exp(RTαaF(E−E0,1))
For the cathode (M₂), the cathodic current density ic is:
ic=i0,2exp(−RTαcF(E−E0,2))
Where:
- i0,1,i0,2 = exchange current densities
- αa,αc = transfer coefficients (typically ~0.5)
- F = Faraday constant
- R = gas constant
- T = temperature
- E0,1,E0,2 = standard reduction potentials
At the mixed potential Emix:
Igalvanic=A1⋅ia(Emix)=A2⋅ic(Emix)
Where A1 and A2 are the surface areas of the anode and cathode.
Why this holds: The net current from the anode must exactly balance the net current consumed at the cathode — otherwise, charge would accumulate, which is impossible in a steady-state circuit.
4. The Corrosion Rate Formula
The corrosion rate (mass loss per time) of the anode is given by Faraday's law:
Corrosion rate=n⋅F⋅ρIgalvanic⋅M
Where:
- M = molar mass of the anode metal
- n = number of electrons transferred per atom
- ρ = density of the metal
- F = Faraday constant (96,485 C/mol)
Why this holds: Each mole of metal oxidized releases n moles of electrons. The total charge passed Q=Igalvanic⋅t corresponds to moles of metal lost:
moles lost=nFQ=nFIgalvanic⋅t
Multiply by M/ρ to get volume or thickness loss.
5. The Area Effect: Why It Matters
From the mixed potential equation:
A1⋅ia(Emix)=A2⋅ic(Emix)
If the cathode area A2 is large relative to the anode area A1, then ia(Emix) must be large to balance the current. This means:
- Small anode + large cathode → severe galvanic corrosion (high current density on the anode). …
The key idea is Faraday’s laws of electrolysis combined with the electrochemical series and overpotential — the product discharged at each electrode depends on which ion is more easily oxidised/reduced under the given conditions.
(i) AgNO₃ (aq) with silver electrodes
- Cathode: Ag⁺ is reduced more easily than H₂O → Ag metal deposits.
- Anode: The silver electrode itself oxidises (Ag → Ag⁺ + e⁻) rather than NO₃⁻ or H₂O.
- Net: Silver dissolves from the anode and plates onto the cathode.
(ii) AgNO₃ (aq) with platinum electrodes
- Cathode: Same as above — Ag⁺ reduces to Ag metal.
- Anode: Pt is inert; NO₃⁻ is not easily oxidised. Water oxidises instead: 2H2O→O2+4H++4e− → O₂ gas evolves.
(iii) Dilute H₂SO₄ with platinum electrodes
- Cathode: H⁺ (from acid) reduces to H₂ gas (2H++2e−→H2).
- Anode: Water oxidises to O₂ gas (as above). …
Electrolysis predictions depend on the electrode material (active vs. inert) and the relative discharge potentials of ions present. For AgNO₃ with Ag electrodes, Ag deposits at cathode and Ag dissolves at anode. With Pt electrodes, Ag deposits at cathode but O₂ evolves at anode. For dilute H₂SO₄ with Pt, H₂ and O₂ evolve (water electrolysis). For CuCl₂ with Pt, Cu deposits and Cl₂ evolves.
The Core Idea: Why Electrolysis Predictions Work
Electrolysis is about forcing a non-spontaneous redox reaction using electrical energy. The key question is always: which ion gets reduced at the cathode, and which gets oxidised at the anode?
The answer depends on two things:
- Standard reduction potentials — the more positive (or less negative) the potential, the easier it is to reduce that species.
- Overpotential — some gases (especially O₂ and H₂) require extra voltage to form, which can shift the order.
- Electrode material — if the anode is made of a metal like Ag or Cu, it can itself get oxidised instead of the anions in solution.
Let's apply this logic to each case.
(i) Aqueous AgNO₃ with silver electrodes
Cathode: Possible reductions:
- Ag++e−→Ag(s), E∘=+0.80 V
- 2H2O+2e−→H2+2OH−, E∘=−0.83 V (at pH 7)
Ag⁺ has a much higher reduction potential, so Ag metal deposits on the cathode.
Anode: Possible oxidations:
- Ag(s)→Ag++e−, E∘=−0.80 V (reverse of reduction)
- 2H2O→O2+4H++4e−, E∘=−1.23 V
- NO3− is very hard to oxidise (nitrate is stable)
The silver electrode itself can oxidise more easily than water. So the anode dissolves: Ag atoms lose electrons and go into solution as Ag⁺.
With an active anode (same metal as the cation in solution), the anode dissolves and the cathode deposits the same metal. This is the principle behind electrorefining of silver.
Products: Cathode — Ag(s); Anode — Ag⁺ goes into solution (electrode dissolves).
(ii) Aqueous AgNO₃ with platinum electrodes
Cathode: Same as above — Ag⁺ reduction is favoured. Ag deposits.
Anode: Now the electrode is inert (Pt doesn't oxidise easily). So we compare:
- 2H2O→O2+4H++4e−, E∘=−1.23 V
- NO3− oxidation: nitrate is extremely stable in water; its oxidation potential is much more negative.
Water oxidation to O₂ is the only feasible reaction. So oxygen gas evolves at the anode.
A common mistake is to think NO₃⁻ gets oxidised. In aqueous solution, nitrate ions are almost never discharged at the anode because water oxidises more easily. The same applies to sulphate, phosphate, etc.
Products: Cathode — Ag(s); Anode — O₂(g) + H⁺ (solution becomes acidic).
(iii) Dilute H₂SO₄ with platinum electrodes
This is essentially electrolysis of water with an inert electrolyte to make it conductive.
Cathode: Possible reductions:
- 2H++2e−→H2, E∘=0.00 V (but in dilute solution, [H⁺] is low, so effective potential is slightly negative)
- 2H2O+2e−→H2+2OH−, E∘=−0.83 V
H⁺ reduction is much easier. Hydrogen gas evolves.
Anode: Possible oxidations:
- 2H2O→O2+4H++4e−, E∘=−1.23 V
- SO42− oxidation: sulphate is very stable; its discharge potential is much more negative than water's.
So oxygen gas evolves.
For dilute H₂SO₄ with inert electrodes:
Cathode: 2H++2e−→H2 …
- COMEDK 2026Set 2026-A1 markMCQQ.The ΔG∘ for the reaction, Cd2+(aq)+Zn(s)→Zn2+(aq)+Cd(s) is: [ECd2+/Cdo=−0.403,EZn2+/Zno=−0.763 V] (A) −69.5kJ (B) −72.2kJ (C) −44.5kJ (D) −50kJ
›Reveal solutionSolution
The standard Gibbs free energy change is found from the cell potential using ΔG∘=−nFEcell∘. Here Ecell∘=+0.360 V and n=2, giving ΔG∘≈−69.5 kJ, so the correct option is (A).
The key idea is that the standard Gibbs free energy change for a redox reaction is directly related to the standard cell potential by ΔG∘=−nFEcell∘. A positive cell potential means the reaction is spontaneous (negative ΔG∘), and a negative cell potential means it is non-spontaneous (positive ΔG∘). Here, we are given two half-cell reduction potentials; we must combine them correctly to get the cell potential for the reaction as written.
-
Identify the half-reactions and their standard reduction potentials.
- Cadmium: Cd2++2e−→Cd(s), E∘=−0.403 V
- Zinc: Zn2++2e−→Zn(s), E∘=−0.763 V
-
Determine which half-reaction is oxidation and which is reduction in the given overall reaction.
The reaction is: Cd2+(aq)+Zn(s)→Zn2+(aq)+Cd(s).
- Zn(s) loses electrons to become Zn2+: this is oxidation.
- Cd2+ gains electrons to become Cd(s): this is reduction. So the cell is: Zn(s)∣Zn2+(aq)∣∣Cd2+(aq)∣Cd(s).
-
Calculate the standard cell potential Ecell∘.
The standard cell potential is:
Ecell∘=Ecathode∘−Eanode∘
Here, the cathode (reduction) is Cd2+/Cd and the anode (oxidation) is Zn2+/Zn.
Ecell∘=(−0.403 V)−(−0.763 V)=+0.360 V
TipA common mistake is to subtract the wrong way or to add the potentials. Remember: Ecell∘=Ereduction at cathode∘−Ereduction at anode∘. Since both given values are reduction potentials, this formula works directly.
- Determine the number of electrons transferred (n). Both half-reactions involve 2 electrons: Cd2++2e−→Cd and Zn→Zn2++2e−. So n=2. …
-
- COMEDK 2026Set 2026-A1 markMCQQ.
[!FORMULA] Using the data given below, the strongest reducing agent is: ECr2O7o2−/Cr3+=1.33 VECl2/Cl−O=1.36 VEMnO4−/Mn2+o=1.51 VECr3+/CrO=−0.74 V
(A) Cr (B) Mn2+ (C) Cr3+ (D) Cl−›Reveal solutionSolution
The strongest reducing agent is the species that is most easily oxidized, which corresponds to the most negative reduction potential. Among the given options, Cr(s) has the most negative reduction potential (−0.74 V), so it is the strongest reducing agent.
The key concept here is the relationship between reduction potential and reducing strength. A reducing agent is a species that donates electrons (gets oxidized). The more easily it donates electrons, the stronger it is as a reducing agent. In electrochemistry, the tendency to be oxidized is the opposite of the tendency to be reduced. So, a very negative reduction potential means the species is very hard to reduce — which means its oxidized form is very stable, and the reduced form (the species itself) is very eager to give up electrons. Thus, the more negative the standard reduction potential, the stronger the reducing agent.
Let’s work through the data step by step.
-
List the given half-reactions and their standard reduction potentials (E°)
- Cr2O72−+14H++6e−→2Cr3++7H2O E∘=+1.33 V
- MnO4−+8H++5e−→Mn2++4H2O E∘=+1.51 V
- Cl2+2e−→2Cl− E∘=+1.36 V
- Cr3++3e−→Cr E∘=−0.74 V
-
Identify the species that are candidates as reducing agents
The question asks for the strongest reducing agent among the options:
(A) Cr (B) Mn²⁺ (C) Cr³⁺ (D) Cl⁻
These are the reduced forms of the couples given. For each, we look at the reduction potential of the couple where that species appears on the right (as the product of reduction).
- For Cr(s): the couple is Cr3+/Cr with E∘=−0.74 V.
- For Mn²⁺: the couple is MnO4−/Mn2+ with E∘=+1.51 V.
- For Cr³⁺: the couple is Cr2O72−/Cr3+ with E∘=+1.33 V.
- For Cl⁻: the couple is Cl2/Cl− with E∘=+1.36 V.
-
Compare reducing strength using the reduction potentials
The more negative the reduction potential, the stronger the reducing agent. Here:
- Cr: E∘=−0.74 V (negative → strong reducing agent) …
-
- COMEDK 2026Set 2026-M1 markMCQQ.Consider a Galvanic cell in which the following reactions occurs: Fe2+(aq)+Ag+(aq)→Fe3+(aq)+Ag(s). What is the standard potential of the cell? Given: E0(Ag+/Ag)=aVE0(Fe2+/Fe)=bV&E0(Fe3+/Fe)=cV (A) (a+2b−3c)V (B) (a+b+2c)V (C) (a−2c+b)V (D) (a+c−2b)V
›Reveal solutionSolution
Ecell∘=Ecathode∘−Eanode∘. Since E∘(Fe3+/Fe2+) isn't given directly, derive it from the two iron couples via ΔG∘=−nFE∘: it equals 3c−2b. Then Ecell∘=a−(3c−2b)=(a+2b−3c)V — option (A).
Concept
A galvanic cell's standard potential is Ecell∘=Ecathode∘−Eanode∘ (both as reduction potentials). Here we must first build E∘(Fe3+/Fe2+) from the given couples, and potentials are combined through Gibbs energy, not added directly.
Solution
-
Half-reactions. Reduction (cathode): Ag++e−→Ag, E∘=a. Oxidation (anode): Fe2+→Fe3++e−, i.e. the Fe3+/Fe2+ couple.
-
Derive E∘(Fe3+/Fe2+). With ΔG∘=−nFE∘:
Fe3++3e−→Fe: ΔG1=−3Fc,Fe2++2e−→Fe: ΔG2=−2Fb.
Subtracting gives Fe3++e−→Fe2+: …
-
- KCET 2026Set D31 markMCQQ.Given below are the half-cell reactions: Mn2+ + 2e− → Mn (E° = -1.18 V) Mn3+ + e− → Mn2+ (E° = +1.51 V) The E°cell for 3 Mn2+ → Mn + 2Mn3+ will be __________ (A) - 2.69 V, the reaction will not occur (Non-Spontaneous) (B) 2.69 V, the reaction will occur (Spontaneous) (C) - 0.33 V, the reaction will not occur (Non-Spontaneous) (D) - 0.33 V, the reaction will occur (Spontaneous)
›Reveal solutionSolution
E° values cannot be added directly when the electron counts differ; converting each half-reaction to ΔG°, combining, and converting back gives E°cell=−2.69 V, so the disproportionation is non-spontaneous.
Step 1 — Set up the target reaction from the given half-reactions
We are given:
Mn2++2e−→MnE°1=−1.18 V(n1=2)
Mn3++e−→Mn2+E°2=+1.51 V(n2=1)
We need E° for 3Mn2+→Mn+2Mn3+, obtained by adding the first equation to twice the reverse of the second equation:
Mn2++2e−→Mn
2×(Mn2+→Mn3++e−)
Adding gives 3Mn2+→Mn+2Mn3+, with the 2e− cancelling — an overall n=2 electron process.
Step 2 — Convert each step to ΔG° (never add E° values directly)
ΔG°1=−n1FE°1=−(2)F(−1.18)=+2.36F
Reversing the second half-reaction flips the sign of E°2; doubling it doubles ΔG° (since ΔG°, unlike E°, is extensive):
ΔG°2, reversed×2=−(2)F(−1.51)=+3.02F …
- KCET 2025Set D-41 markMCQQ.Match List-I with List-IIChoose the correct answer from the options given below. (A) a-iv, b-iii, c-i, d-ii (B) a-ii, b-i, c-iv, d-iii (C) a-iii, b-iv, c-i, d-ii (D) a-iii, b-ii, c-i, d-iv
List-I (Types of redox reactions) List-II (Examples) a. Combination reaction i. ClX2X(g)+2BrX−X(aq) →2ClX−X(aq)+BrX2X(l) b. Decomposition reaction ii. 2HX2OX2X(aq) →2HX2OX(l)+OX2X(g) c. Displacement reaction iii. CHX4X(g)+2OX2X(g) →COX2X(g)+2HX2OX(l) d. Disproportionation reaction iv. 2HX2OX(l) →2HX2X(g)+OX2X(g) ›Reveal solutionSolution
Assign oxidation numbers in each of the four example reactions and name the redox type from what the numbers do — one substance formed (combination), one substance split (decomposition), one element pushing another out (displacement), or one element going both up and down (disproportionation).
Step 1 — Fix the four definitions
- Combination redox: two substances combine to give one product, with an oxidation-number change. General form A+BAB.
- Decomposition redox: a single compound breaks into two or more products, with an oxidation-number change. General form ABA+B.
- Displacement redox: a more reactive element displaces a less reactive one from its compound. General form X+YZXZ+Y.
- Disproportionation: one element in one substance is simultaneously oxidised and reduced. This requires the element to have an intermediate oxidation state, so it has somewhere to go both up and down.
Step 2 — Example (iii): CHX4X(g)+2OX2X(g)ΔCOX2X(g)+2HX2OX(l)
Carbon: −4 in CHX4 → +4 in COX2 (oxidised).
Oxygen: 0 in OX2 → −2 in COX2 and HX2O (reduced).
Methane and oxygen combine into the products, so this is a combination reaction. a→iii
Step 3 — Example (iv): 2HX2OX(l)electrolysis2HX2X(g)+OX2X(g)
Hydrogen: +1→0 (reduced). Oxygen: −2→0 (oxidised).
A single compound splits into two elements — a textbook decomposition reaction. b→iv
Step 4 — Example (i): ClX2X(g)+2BrX−X(aq)2ClX−X(aq)+BrX2X(l)
Chlorine: 0→−1 (reduced). Bromine: −1→0 (oxidised). …
- COMEDK 2025Set 2025-A1 markMCQQ.What is the standard electrode potential at 298 K for the reaction: Cu2++1e−→Cu+1 ? Given: E0Cu+1/Cu=0.5 V&E0Cu+2/Cu=0.335 V (A) 0.34V (B) 0.17V (C) 0.492V (D) 0.410V
›Reveal solutionSolution
The key is to combine the given half‑reactions using Gibbs free energy, not simply average the potentials. The standard potential for Cu2++e−→Cu+ is 0.170 V, which corresponds to option (B).
The trap here is that electrode potentials are not additive like voltages in series. Because they are intensive properties (energy per charge), you must convert each potential to a Gibbs free energy change (ΔG∘=−nFE∘), sum the free energies, and then convert back to a potential for the desired half‑reaction.
Step‑by‑step reasoning
-
Write the given half‑reactions and their standard potentials
- (1) Cu++e−→Cu E1∘=+0.50 V, n1=1
- (2) Cu2++2e−→Cu E2∘=+0.335 V, n2=2
-
Convert each to Gibbs free energy
Use ΔG∘=−nFE∘ (with F the Faraday constant; it cancels later).
- For (1): ΔG1∘=−1⋅F⋅0.50=−0.50F
- For (2): ΔG2∘=−2⋅F⋅0.335=−0.67F
-
Find the free energy for the target half‑reaction
Target: Cu2++e−→Cu+
This can be obtained by reversing reaction (1) and adding it to reaction (2):
- Reverse (1): Cu→Cu++e− gives ΔG∘=+0.50F
- Add to (2): Cu2++2e−→Cu gives ΔG∘=−0.67F
- Sum: Cu2++e−→Cu+ …
-
- COMEDK 2025Set 2025-A1 markMCQQ.The Standard Reduction potential at 25∘C for (MnO4)−1/H+is +1.49 V . The E0 values for four Metal ions : (a). Co3+/Co2+ (b). Cr3+/Cr (c). Au3+/Au and (d). Ag+/Ag are +1.81 V,−0.74 V,+1.50 V and +0.8 V respectively. Identify two of them which cannot be oxidised by (MnO4)−1/H+ (A) a & d (B) a & c (C) b & d (D) b & c
›Reveal solutionSolution
The key idea is that a species can be oxidised by permanganate only if its reduction potential is lower than +1.49 V. Comparing the given potentials shows that Co³⁺/Co²⁺ (+1.81 V) and Au³⁺/Au (+1.50 V) are both higher, so they cannot be oxidised. The correct option is (B).
Concept & Intuition
The standard reduction potential E∘ measures how easily a species gains electrons (is reduced). A higher E∘ means a stronger oxidising agent — it readily takes electrons. Permanganate in acid, MnO4−/H+, has E∘=+1.49 V. For it to oxidise a metal ion, that metal ion’s reduction potential must be lower than 1.49 V. Why? Because the metal ion would need to lose electrons (be oxidised), and that is the reverse of its reduction half-reaction. The reverse reaction’s tendency is given by −E∘. If the metal ion’s E∘ is greater than permanganate’s, then the metal ion is actually a stronger oxidant than permanganate — it won’t give up electrons to permanganate; instead, permanganate would be the one reduced. So we simply check which metals have E∘>+1.49 V.
Step-by-step reasoning
-
List the given reduction potentials
- MnO4−/H+: E∘=+1.49 V
- (a) Co3+/Co2+: +1.81 V
- (b) Cr3+/Cr: −0.74 V
- (c) Au3+/Au: +1.50 V
- (d) Ag+/Ag: +0.80 V
-
Compare each to +1.49 V
- For a metal ion to be oxidised by permanganate, its reduction potential must be less than 1.49 V.
- (a) 1.81>1.49 → cannot be oxidised. …
-
- COMEDK 2024Set 2024-E1 markMCQQ.Arrange the following redox couples in the increasing order of their reducing strength: [A]=Cu/Cu2+[ B]=Ag/Ag+[C]=Ca/Ca2+[D]=Cr/Cr3+E0=−0.34 VE0=−0.8 VE0=+2.87 VE0=+0.74 V (A) B < A < D < C (B) A < C < B < D (C) C < D < A < B (D) D < A < C < B
›Reveal solutionSolution
With the couples written as M/Mn+ (oxidation potentials), reducing strength rises with the potential value: Ag(−0.8)<Cu(−0.34)<Cr(+0.74)<Ca(+2.87), i.e. B < A < D < C.
The couples are given as M/Mn+ with these values (oxidation potentials):
- [A] Cu/Cu2+: −0.34 V
- [B] Ag/Ag+: −0.8 V
- [C] Ca/Ca2+: +2.87 V
- [D] Cr/Cr3+: +0.74 V
A stronger reducing agent is more easily oxidised, i.e. has the more positive oxidation potential. Arranging in increasing order of these values: …
- KCET 2022Set B-31 markMCQQ.All Cu(II) halides are known, except the iodide, the reaction for it is that (A) Cu^{2+} has much more negative hydration enthalpy (B) Cu^{2+} ion has smaller size (C) Iodide is bulky ion (D) Cu^{2+} oxidises iodide to iodine
›Reveal solutionSolution
Cu2+ and I− cannot coexist: a redox reaction destroys the would-be CuI2, giving Cu2I2 and I2.
Step 1 — The observation to explain.
CuF2, CuCl2 and CuBr2 all exist, but CuI2 does not. So the question is: what is special about iodide?
Step 2 — The redox answer.
Iodide is the most easily oxidised halide (largest, most polarisable, lowest ionisation energy for the extra electron; EI2/I−∘=+0.54 V, the least positive of the halogen couples). Copper(II) is a mild oxidant that becomes a strong one when the product Cu+ can be locked away as an insoluble salt — and CuI is exactly that. So the moment you try to make CuI2, the ions react:
2Cu2++4I−⟶Cu2I2↓ (i.e. 2CuI)+I2
Cu2+ is reduced to Cu+ while I− is oxidised to I2. The driving force is twofold: (i) the very favourable lattice/solubility term — CuI is highly insoluble, which pulls the equilibrium over; and (ii) iodide's low oxidation potential. With F−,Cl−,Br− this electron transfer is not favourable enough, so their Cu(II) halides survive.
This is the same redox pair used in the classic iodometric estimation of copper, where the liberated I2 is titrated with hypo (Na2S2O3) — proof that the reaction really runs.
Step 3 — Reject the others. …
- KCET 2021Set B-21 markMCQQ.HX2X(g)+2AgClX(s) ⇌2AgX(s)+2HClX(aq) Ecell∘ at 25∘C for the cell is 0.22V. The equilibrium constant at 25∘C is (A) 2.8×107 (B) 5.2×108 (C) 2.8×105 (D) 5.2×104
›Reveal solutionSolution
Link thermodynamics to electrochemistry via ΔG∘=−nFE∘=−RTlnK, which at 298 K reduces to logK=nE∘/0.059.
Step 1 — Find n from the balanced cell reaction.
H2(g)+2AgCl(s)⇌2Ag(s)+2HCl(aq)
Oxidation: H2→2H++2e−
Reduction: 2AgCl+2e−→2Ag+2Cl−
Electrons transferred: n=2.
Step 2 — The bridge between E∘ and K.
At equilibrium the cell is dead (Ecell=0, Q=K), so the Nernst equation
Ecell=Ecell∘−n0.059logQ
gives
0=Ecell∘−n0.059logK⟹logK=0.059nEcell∘.
(Equivalently from ΔG∘=−nFE∘=−RTlnK at T=298K.)
Step 3 — Substitute.
logK=0.0592×0.22=0.0590.44=7.457.
Step 4 — Take the antilog. …
- COMEDK 2021Set 2021-B1 markMCQQ.X + e^- -> X^- and Y + e^- -> Y^-, are two half-cell reaction with their reduction potential, values as 1.78V and 1.09 V, it follows that : (A) X is more easily oxidized than Y (B) Y is more easily oxidized than X (C) Y will be a better oxidized agent (D) X will be a better oxidizing agent.
›Reveal solutionSolution
A higher reduction potential means a greater tendency to be reduced (to gain electrons); since EX∘=1.78V>EY∘=1.09V, X is the stronger oxidising agent.
Reasoning. The reduction potential measures how easily a species accepts electrons (is reduced). The larger the value, the stronger the oxidising agent.
EX∘=1.78V,EY∘=1.09V,EX∘>EY∘ …
🎓Unlock everything free for 14 days
- ✓Full step-by-step solutions
- ✓Concept-first explanations
- ✓Methods, shortcuts & mistakes
- ✓PYQ mapping + timed mock tests
Full access for 14 days. No credit card required.