Q.Can the potential barrier across a p-n junction be measured by simply connecting a voltmeter across the junction?
You're viewing a preview — the full solution, concept, methods & PYQ mapping are locked.
Start your 14-day free trial to unlock the full solution →No, a voltmeter cannot measure the built-in potential barrier of a p-n junction because the contact potentials at the metal-semiconductor junctions cancel the barrier voltage, and any measurement circuit would disturb the equilibrium.
Why the Question Matters
This is a classic trick question in semiconductor physics. Many students assume that since a p-n junction has a potential barrier (typically 0.3–0.7 V for silicon), you should be able to read that voltage directly with a voltmeter. But that assumption misses a subtle but crucial point: the voltmeter itself becomes part of the circuit, and the physics of contacts between different materials changes everything.
Let’s understand why.
The Core Concept: Contact Potentials
When you connect a voltmeter to a p-n junction, you are not just touching the p-side and n-side with identical wires. You are creating a chain of different materials:
- Metal wire (say copper) from voltmeter terminal → contact with p-type silicon
- p-type silicon → n-type silicon (the junction itself)
- n-type silicon → contact with another metal wire → back to voltmeter
Every junction between two different materials develops its own contact potential (also called built-in potential or work-function difference). The voltmeter reads the net voltage around the entire loop, not just the p-n junction barrier.
Step-by-Step Reasoning
-
The p-n junction at equilibrium has a built-in potential across its depletion region. This potential arises because diffusion of majority carriers across the junction leaves behind fixed ionized impurities, creating an electric field that opposes further diffusion. At equilibrium, the net current is zero.
-
Now consider what happens when you attach metal probes. Each metal-semiconductor contact also forms a junction with its own built-in potential. For a metal with work function contacting a semiconductor with electron affinity , the contact potential is (plus doping-dependent corrections).
-
The complete circuit forms a closed loop. Going around: metal₁ → p-Si → n-Si → metal₂ → voltmeter → back to metal₁. Kirchhoff’s voltage law says the sum of all potential differences around this loop must be zero at equilibrium (no external battery).
-
The voltmeter reads the net voltage across its terminals. That net voltage is the sum of:
- Contact potential at metal₁–p-Si junction
- Built-in potential of p-n junction ()
- Contact potential at n-Si–metal₂ junction
- Any potential drops in the wires (negligible)
-
Here’s the key insight: At equilibrium, the sum of all these contact potentials exactly cancels the p-n junction barrier. The net voltage around the loop is zero. The voltmeter reads zero.
A common mistake is to think the voltmeter reads directly. But the metal-semiconductor contacts are not ohmic — they are rectifying or at least have their own built-in potentials. Even if you try to make ohmic contacts (by heavily doping the contact regions), the contact potentials still adjust to cancel the junction voltage in equilibrium. …