Q.State any two sources of error in meter bridge experiment. Explain how they can be minimised.
You're viewing a preview — the full solution, concept, methods & PYQ mapping are locked.
Start your 14-day free trial to unlock the full solution →The two main sources of error in a meter bridge are end resistance at the copper strips and non-uniformity of the bridge wire; both are corrected by calibration/measurement technique rather than by circuit change.
(1) End resistance (end correction): The resistance of the copper strips at the two ends of the meter bridge wire, and of the connections/jockey contact, adds an unknown extra resistance not accounted for by the measured length alone, causing a small error in the balance-point reading.
Minimisation: Determine the end correction experimentally (by interchanging known resistances in the two gaps and comparing the calculated vs. actual balance lengths), and add this correction to every observed balancing length; alternatively, keep the unknown and known resistances comparable so the balance point falls near the middle of the wire, where end effects influence the percentage error least.
(2) Non-uniform cross-section / material of the wire: If the meter-bridge wire does not have a strictly uniform cross-sectional area or uniform resistivity along its length, the assumption (resistance proportional to length) breaks down, introducing error. …